5.17 PULSE DIAL RATIO (PGM 176)

In LDK-300, pulse dial speed ratio is set only for 10 PPS.

PROCEDURE

PULSE DIAL RATIO

(1:66/33 0:60/40) : 66/33

(1)  [TRANS/PGM] + 176.

PULSE DIAL RATIO

(1:66/33 0:60/40) : 60/40

(2)  To assign Pulse Dial Ratio, press the one digit 0-1 as TABLE 5.17.1. Then the selected value will be displayed on the LCD. (Ex. digit 0: 60/40)

PULSE DIAL SPD RATIO

(1:66/33 0:60/40) : 60/40

(3)  Press the [HOLD/SAVE] button for updating database permanently.

DGT

PULSE DIAL SPEED RATIO

REMARK

1

10 PPS 66/33 %

defaults

0

10 PPS 60/44 %

TABLE 5.17.1 Button Configuration for Pulse Dial Speed Ratio (PGM 176)

5.18 SMDR ATTRIBUTES (PGM 177)

Station Message Detail Recording (SMDR) will provide details on both incoming and outgoing calls. As an assignable database option, if All Call record type is selected, incoming and outgoing local and long distance calls are all provided. If only Long Distance is selected, then only outgoing calls that meet the toll check status requirements listed below are provided.

PROCEDURE

SMDR ATTRIBUTES

PRESS FLEX_KEY (01-14)

(1)  [TRANS/PGM] + 177. To program SMDR attributes, use the BTNs as TABLE 5.18.1.

SMDR SAVE

(1 : ON/ 0: OFF) : OFF

l  To program SMDR save mode, press the Flex. BTN 1. The LCD will show the current related field status. User can change the value by pressing one digit. Press the [HOLD/SAVE] button to save it.

SMDR PRINT

(1 : ON/ 0: OFF) : ON

l  To program SMDR print mode, press the Flex. BTN 2. The LCD will show the current related field status. User can change the value by pressing one digit. Press the [HOLD/SAVE] button to save it.

RECORD TYPE

(1 : LD/ 0: ALL) : LD

l  To program SMDR recording call type, press the Flex. BTN 3. The LCD will show the current related field status. User can change the value by pressing one digit. Press the [HOLD/SAVE] button to save it.

LD CALL DGT CNT

(07-15) : 07

l  To program SMDR long distance call digit counter, press the Flex. BTN 4 and dial 2 digits. (Ex. 07) Then the LCD will be changed to the current related field status. Press the [HOLD/SAVE] button to save it.

PRINT INCOMING CALL

(1 : ON/ 0: OFF) : OFF

l  To program SMDR incoming call print mode, press the Flex. BTN 5. Then the LCD will show the current related field status. User can change the value by pressing one digit. Press the [HOLD/SAVE] button to save it.

PRINT LOST CALL

(1 : ON/ 0: OFF) : ON

l  To program SMDR lost call print mode, press the Flex. BTN 6. Then the LCD will show the current related field status. User can change the value by pressing one digit. Press the [HOLD/SAVE] button to save it.

RECORD IN DETAIL

(1 : ON/ 0: OFF) : ON

l  To program the record detailed SMDR, press the Flex. BTN 7. Then the LCD will show the current related field status. User can change the value by pressing one digit. Press the [HOLD/SAVE] button to save it.

HIDDEN DIALED DGT

( 0 – 9 ) : 7

l  To program SMDR dial digit hidden, press the Flex. BTN 8 and dial one digit. (Ex. 7) Then the LCD will be changed to the current related field status. Press the [HOLD/SAVE] button to save it.

SMDR CURRENCY UNIT

ABC

l  To assign currency unit, press the Flex. BTN 9. Then the LCD will be changed to the current related field status. Refer to the English Character Set to enter currency unit. Press the [HOLD/SAVE] button to save it.

COST PER PULSE (6DGT)

000000

l  To program SMDR cost per unit pulse, press the Flex. BTN 10 and dial 6 digits. Then the LCD will be changed to the current related field status. Press the [HOLD/SAVE] button to save it.

SMDR FRACTION

(0-5) : 0

l  To program SMDR fraction, press the Flex. BTN 11 and dial one digit. Then the LCD will be changed to the current related field status. Press the [HOLD/SAVE] button to save it.

LONG DISTANCE CODE

0

l  To program SMDR long distance codes, press the Flex. BTN 14. Then the current related field status on the LCD. Press 1-5 Flex. BTN and dial maximum 2 digits. Press the [HOLD/SAVE] button to save it.

SMDR ATTRIBUTES

PRESS FLEX_KEY (1-14)

(2)  Press the [HOLD/SAVE] button for updating database permanently.

SMDR ATTRIBUTES

PRESS FLEX_KEY (1-14)

l  Press the [CONF] button instead of the [HOLD/SAVE] button, then system goes to step (1) without updating system memory

BTN

ITEM

RANGE

DEFAULT

REMARK

1

SMDR Save Enable

ON/OFF

OFF

The system can be set to save SMDR record or not.

2

SMDR Print Enable

ON/OFF

OFF

The system can be set to real time print.

3

Long Distance / All Call Recorded

LD/All Call

LD

The system can be set to record either all outgoing calls or only long distance calls, exceeding time limit set by SMDR Start Timer. The long distance calls are identified by programmed SMDR long distance code (BTN 14).

4

SMDR Long Distance Call Digit Counter

07-15

07

If SMDR digit counter is more than this value, it is considered as long distance call.

5

Print Incoming Call

ON/OFF

OFF

If this option (PIC) is set to Enable, all incoming calls are printed with either all outgoing calls or long distance calls.

6

Print Lost Call

ON/OFF

ON

If this option (PLC) is set to Enable, all lost calls are printed with either unanswered or not.

7

Records in Detail

ON/OFF

ON

Due to limited system memory size, in places where many calls take place, the SMDR record buffer can easily saturated. So, if the customer doesn't need the detailed call information but total call, total metering count and total cost for individual station, then it is possible to save only the total accumulation, rather than the whole detailed records.

8

SMDR Dial Digit Hidden

0-9

0

According to this value, SMDR dial digit will be hidden and ‘*’ symbol will be displayed instead of the hidden digits.

9

SMDR Currency Unit

3 Chars

-

For easy identification of call cost, the currency unit can be entered with 3 alphabet characters to be printed in front of call charge amount.

10

SMDR Cost Per Unit Pulse

6 digits

-

This is the call cost unit per cost metering pulse, which is sent from the Central Office.

11

SMDR Fraction

0-5

0

This value means the decimal position point of the cost per unit pulse.

12

SMDR Start Timer

000-250

000

1 sec base

13

SMDR Hidden Digit

Right/

Left

Right

Hide digits from right or left

14

SMDR Long Distance Codes

Flex. BTN 1 – 5

0

Max. 5 SMDR long distance codes are available. SMDR long distance code is 1 or 2 digit number. By default, SMDR long distance code is 0.

TABLE 5.18.1 Button Configuration for SMDR Attributes (PGM 177)

5.19 SYSTEM TIME/DATE SETTING (PGM 178)

In LDK-300, date and time can be set by Admin programming, and it will be shown in the LCD of stations.

PROCEDURE

SET SYSTEM TIME/DATE

PRESS FLEX_KEY

(1)  [TRANS/PGM] + 178.

SET SYSTEM TIME/DATE

TIME 12:30 (HH:MM)

l  To program the system time, press the Flex. BTN 1 and enter Hour/Minute (HHMM) in 24-hour format. Then the LCD will be changed to the current related field status.

SET SYSTEM TIME/DATE

DATE: 05/10/00 (MMDDYY)

l  To program the system date, press the Flex. BTN 2 and enter Month/Date/Year (MMDDYY) format. Then the LCD will be changed to the current related field status.

SET SYSTEM TIME/DATE

PRESS FLEX_KEY (1-2)

(2)  Press the [HOLD/SAVE] button for updating database permanently.

SET SYSTEM TIME/DATE

PRESS FLEX_KEY (1-2)

l  Press the [CONF] button instead of the [HOLD/SAVE] button, then system goes to step (1) without updating system memory

BIN

ITEM

RANGE

DEFAULT

REMARK

1

System Time

4 digits

-

Hour/Min in sequence

2

System Date

6 digits

-

Month/Day/Year in sequence

TABLE 5.19.1 System Time/Date Setting (PGM 178)