7. DCOB ATTRIBUTE (PGM 186 - PGM 187)
7.1 DCOB SYS Attribute (PGM 186)
PROCEDURE
DCOB SYS ATTRIBUTE PRESS FLEX KEY(01-11) | (1) [TRANS/PGM] + 186 |
R2 OUT MANAG TMR(sec) (01 – 50) : 14 | (2) To program DCOB System Attribute, Press the Flex Btn 1-11. Related message will be displayed on LCD. (EX: Btn3) |
R2 OUT MANAG TMR(sec) (01 – 50) : 30 | (3) To change the value, dial the value in the range (EX:30) |
R2 OUT MANAG TMR(sec) (01 – 50) : 30 | (4) Press the [HOLD/SAVE] button for saving database permanently. |
DCOB SYS ATTRIBUTE PRESS FLEX KEY(01-11) | l Press [CONF] button instead of the [HOLD/SAVE] button, then system goes to step (1) without updating system memory. |
BTN | ITEM | RANGE | DEFAULT | REMARK |
1 | DCOB CO Type | 0-2 | 2 | 0:Sweden/Cyprus 1:Italy 2:Korea/Australia |
2 | Metering Type | 0-1 | 0 | 0:Not used 1:When received the Metering signal |
3 | R2 OUT Manage Timer | 01-50 | 14 | In R2 signaling, maximum time for waiting for forward signal from PX (1 sec) |
4 | R2 IN Manage Timer | 01-50 | 14 | In R2 signaling, maximum time for waiting for forward signal from PX (1 sec) |
5 | R2 Disappear Timer | 01-50 | 14 | 1 sec |
6 | R2 Pulse Timer | 01-30 | 7 | In R2 signaling, time duration to send pulse typed R2 signal (20 msec) |
7 | R2 Ready Timer | 000-500 | 7 | 20 msec |
8 | Dial Tone Delay Timer | 01-30 | 20 | |
9 | Line Status | 1-9 | 6 | Free Line |
10 | Calling Category | 1-9 | 1 | User no priority |
11 | DNIS Service | ON/OFF | OFF | ON: Caller ID Service |
TABLE 7.1.1 DCOB System Attribute (PGM 186)
7.2 DCOB Co line Attribute (PGM 187)
PROCEDURE
DCOB COLINE ATTR ENTER COL RANGE | (1) [TRANS/PGM] + 187. |
001-002 DCOB CO ATTR PRESS FLEX_KEY (1-2) | (2) Enter CO line range (Ex. 001-002). |
(3) To program, Press BTN 1-2 and enter related data for setting, then entered data will be displayed on the LCD. | |
001-002 IN DGT TYPE (0 – 2) : R2MFC | (4) To assign Incoming Digit Type, press Flex. BTN 1 and dial Digit Type.(Ex: dial 2) |
001-002 IN DGT TYPE (0 – 2) : R2MFC | (5) Press the [HOLD/SAVE] button for updating database permanently. |
001-002 DCOB CO ATTR PRESS FLEX_KEY (1-2) | l Press the [CONF] button instead of the [HOLD/SAVE] button, then system goes to step (2) without updating system memory. |
BTN | ITEM | RANGE | DEFAULT | REMARK |
1 | IN Digit Type | 0-2 | 2 | Default: R2MFC (2) To set type. [0 : PULSE, 1 : DTMF, 2 : RFC] |
2 | OUT Digit Type | 0-2 | 2 | Default: R2MFC(2) To set type. [0 : PULSE, 1 : DTMF, 2 : RFC] |
TABLE 7.2.1 DCOB Co line Attribute (PGM 187)
8. STATION GROUP PROGRAMMING (PGM 190 - PGM 191)
Stations in the system can be grouped so that incoming calls will search (hunt) for an idle station in the group. Three hunting processes can be assigned; Circular, Terminal, or UCD (Uniform Call Distribution). Each of the system's groups is assigned as a function; Call Pick-Up Group and/or Hunt Group, Voice Mail Group, and Ring Group. The available group number and station number in a group is as follows:
System | LDK – 300 |
No. of Group | 48 |
STA No. in a Group | 64 |
1. A station can belong to any number of Pickup groups, but can only belong to one Station Hunt group, Voice mail group or Ring group.
2. When assigning a station group to any type of hunt group or voice mail group, ring, pick up group, the system initializes hunt attributes by default value for it's own function. It can be programmed to meet each customer's individual need.
8.1 STATION GROUP ASSIGN (PGM 190)
PROCEDURE
STATION GRP ASSIGN ENT HUNT NO (VVV - VVV) | (1) [TRANS/PGM] + 190. | |
STATION GRP 620 F1:TYPE F2:PKUP F3:MEM | (2) Enter Station Group Number 620 – 667 (Ex 620). Then user can set the type, pick-up feature and member of the selected group. First, press Flex. BTN 1 and set Type. (see TABLE 8.1.1) | |
STATION GRP 620 NOT ASSIGNED (0-6) | (3) To select Type, press one digit of 0 – 6 (Ex. 1). | |
STATION GRP 620 CIRCULAR GROUP (0-6) | (4) To save, press the [HOLD/SAVE] button for updating database. | |
GROUP 620 PICK-UP (1:ON/0:OFF) : OFF | (5) To set pick_up feature of the Circular Group, press Flex. BTN 2 and enter the desired value. | |
STATION GRP 620 F1:TYPE F2:PKUP F3:MEM | (6) To assign member of the Circular Group, press Flex. BTN 3. | |
CIRCULAR 620 | (7) Choose one of 4 Flex. BTNs, and enter station number step by step or enter the station range (Ex: 100120). | |
| STATION GRP 620 F1:TYPE F2:PKUP F3:MEM | (8) Press the [HOLD/SAVE] button for updating database permanently. User can set another group by going step (1). (Ex. 620 – 667) |
| STATION GRP 620 F1:TYPE F2:PKUP F3:MEM | l Press the [CONF] button instead of the [HOLD/SAVE] button, then system goes to step (1) without updating system memory. |
| ||
DGT | ITEM | RANGE | DEFAULT | REMARK |
1 | Group Type | 0-6 | 0 | 0: Not Assigned 1: Circular 2: Terminal 3: UCD 4: Ring 5: VM 6: Pick up |
2 | Pick-up Attribute | ON/OFF | OFF | OFF |
3 | Member assignment | Not Assigned | - | First, group type should be assigned. |
TABLE 8.1.1 Button Configuration for Station Group Type (PGM 190)
|